OPTISONIC 8300
Ultrasonic flowmeter for cryogenic or high-temperature gases and superheated steam
- 2-path meter with optional mass flow and enthalpy calculation
- Engineered for extreme temperatures: from measurement of BOG and other gases down to -200°C / -328°F to steam and boiler monitoring up to +593°C / +1100°F
- DN100…1000 / 4…40"; max. PN250 / ASME Cl 2500
- Large turndown ratio (60:1)
Overview
The OPTISONIC 8300 is a 2-path ultrasonic flowmeter designed for the measurement of gases under extreme temperature conditions (-200°C…+593°C / -328°F…+1100°F) and at elevated pressures (up to 200 bar / 2900 psi). This makes it a standard solution for boiler and power plant monitoring or as a steam billing device. With connected temperature and pressure sensors, the flowmeter’s integrated flow computer can also calculate steam mass flow or enthalpy.
The OPTISONIC 8300 is equally well-suited for cryogenic gas applications, making it an ideal choice for boil-off gas (BOG) measurement or for flow measurement in air separation rectification (ASR) cold boxes.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Bi-directional flow measurement over a wide dynamic range
- Integrated flow computer option: Mass flow and enthalpy calculation according to IAPWS-IF97
- Current inputs for external pressure and temperature sensors
- Suitable for energy balancing
- High accuracy: <±1% error of measured value (>DN150)
- Extensive online diagnostics and functions for proper meter operation and verification
- Can be certified for custody transfer measurements (only in certain countries applicable)
- Full mechanically safe design for cryogenic applications
- Full bore design: No moving parts, no wear, no pressure loss
- No periodical maintenance or recalibration needed
- Ex d certified stainless steel (316 L) connection box
- ATEX, IECEx, QPS and NEPSI approvals
- Hazardous area process temperatures up to +593°C / +1100°F
- Zone 0 approval for measurement of explosive gas mixtures